ZEG
loader
ASD-1

Produkty

ASD-1
Earth Fault Detection System for DC Circuits
ASD-1 device provides insulation faults detection system dedicated to be used in DC auxilliary circuits. The device constantly monitors the insulation system of ungrounded network. Each feeder is monitored by independent sensor. Two threshold valueas can be set: the warning threshold value and alarm threshold value. Warning and alarms are quickly and preciselly provided to the staff. ASD-1 provides also the event recorder function. Data of event recorder can be transfered to SCADA system by fiber optic communication port, RS-485 or by Ethernet network. Cooperation with SCADA system is possible by following communication protocols: ZEG or IEC 60870-5-103, and optional: MODBUS, DNP3 or IEC61850.

Manuals, diagrams, technical details

DOWNLOAD FILES

Product description

ASD-1 is freely programmable device which monitors the condition of insulation system. Active monitoring of insulation system is carried out by the generator, which adds extra resistance to „+” and „-” poles alternately. Insulation fault, can be seend as extra earth current flow. The extra earth current is detected by current sensor which is part of ASD-1 system. The device shows the condition of insulation system by set of RGB LED diodes and 7” LCD screen. Visualisation of insulation failure signal can be time-delayed. All signals can be grouped to one ALARM or Failure signal. 7” LCD touchscreen allows to control switchgear breakers, settings change, preview of inputs and outputs statuses, language change, preview of time, event recorder or measured values.

Main features

  • constant, active monitoring of insulation system of DC network
  • standard rack 19” cassette of dimensions 19”/4U/160
  • programmable 7” touchscreen allowing to operate and device setting
  • removable front panel with possibility to install in any place
  • optical insulated programmable binary inputs
  • relay outputs for failure signalling purposes – programmable
  • 32/64 measuring inputs per section
  • 32 programmable RGB LED’s
  • watchodag contact for lack of auxilliary voltage or power module failure signalling purposes
  • back-up power module
  • binary inputs for remote acknowledgment signal
  • in/out modules equipped with screwable 16-pins terminals
  • possibility to upgrade the system to any number of feeding sections
  • Alarm ON/OFF button allows to disengage ALARM and Failure signals
  • Alarm C button allows to acknowledge ALARM and Failure signals
  • 8 communication ports: RS232, RS485, ST-fiber-optic

TECHNICAL DATA

Rated supply voltage

110-220V DC

other value on request

Burden in power module <3 0VA
Number of analog inputs  32/64
Number of binary inputs  5
Number of outputs  8/16
Number of 4U cassettes 1-4
Insulation optical
Input pick-up voltage

Uw=220V DC/AC

other value on request

Burden in binary inputs 0,3W
Settable time delay up to 25s
Time resolution  1ms
Number of communication channel 8
Weight 5kg
Ambient temperature -5 ÷ +40 °C

 


You need more information?

Contact our Sales Department and talk to our expert about the details.